A Randomised Controlled Trial Comparing Thermoformed and 3D-Printed Retainers in Young Adults: Evaluation of Post-treatment Stability and Patient Satisfaction

Document Type

Article

Publication Date

4-1-2026

Abstract

Introduction: To compare post-treatment stability and oral health–related quality of life (OHRQoL) in young adults wearing thermoformed retainers (TFR) versus direct 3D-printed retainers (3DPR) over a six-month part-time retention period. Materials and methods: This single-centre, two-arm parallel randomised controlled trial allocated 30 debonded orthodontic patients (≥ 18 years) to either TFR (Erkodur PETG, 1.0 mm) or 3DPR (NextDent Ortho Flex, 0.75 mm) in a 1:1 ratio. All retainers were worn part-time (8–12 h/day). Digital intraoral scans were obtained at baseline (T0) and six months (T2) using Trios 3, and post-treatment stability was assessed digitally using Little’s Irregularity Index, intercanine width, intermolar width, arch length, overjet, and overbite. OHRQoL was evaluated at both time points using the OHIP-14(M) questionnaire. Non-parametric tests were applied following the Shapiro–Wilk assessment, and analyses were conducted using an intention-to-treat approach. Results: One dropout in the 3DPR group at T2. At T2, no significant between-group differences were found in Little’s Irregularity Index, intercanine width, intermolar width, arch length, or overjet (p > 0.05). Overbite values were statistically higher in the TFR group at T2 (p < 0.05); however, the difference was not clinically significant. Changes in post-treatment stability from T0 to T2 (ΔT2–T0) did not differ significantly between groups (p > 0.05). Total OHIP-14(M) scores improved significantly from T0 to T2 in both groups (TFR p = 0.016; 3DPR p = 0.013), with no significant between-group differences at either time point (p > 0.05). A small but significant difference was observed in the psychological disability domain at T2, with slightly higher scores in the 3DPR group (p = 0.020). No harm was observed. Conclusions: TFR and 3DPR demonstrated comparable post-treatment stability and similar improvements in OHRQoL after six months of part-time wear. Registration: ClinicalTrials.gov (Identifier NCT05968625). Protocol: The protocol was published before trial commencement

Keywords

3D-printed retainers, OHRQoL, Post-treatment stability, Retention, Thermoformed retainers

Publication Title

Clinical Oral Investigations

ISSN

1432-6981

DOI

10.1007/s00784-026-06793-z

Funders

Universiti Malaya

Volume

30

Issue

4

Publisher

Springer Science and Business Media Deutschland GmbH

Share

COinS