Effects of Electrolyte Volume on Electrochemical Migration of Tin in Water Drop Test

Document Type

Article

Publication Date

1-1-2026

Abstract

Miniaturization of electronic devices and the consequent reduction in pitch can increase the risks of short circuit failures due to electrochemical migration (ECM). Water drop test (WDT) is one of the most widely used methods for ECM studies. However, the volume of the electrolyte used in WDT has not been standardized yet. This work investigates the effects of varying electrolyte volume on the ECM of tin (Sn) in WDT, using a two-probe semiconductor characterization system (SCS). The volume of the electrolyte was varied from 5 µL to 100 µL. The electrolytes used for this study are NaCl solutions (0.1, 1, and 10 mM), which are commonly used electrolytes for ECM studies. Results show that the electrolyte volume does not affect the time to failures (TTF) of Sn at low and medium Cl− concentrations (0.1 mM and 1 mM). However, at a high Cl− concentration (10 mM), the TTF increases as the electrolyte volume increases. Results further show that the electrolyte volume and Cl− concentration influence the hydrodynamic conditions of the electrolyte during WDT. The synergistic effects of the electrolyte volume, Cl− concentration, and hydrodynamic conditions in the electrolyte on the ECM behavior of Sn are elucidated.

Keywords

Electrochemical migration, electrolyte volume, hydrodynamics, water drop test

Publication Title

IEEE Transactions on Device and Materials Reliability

ISSN

15304388

DOI

10.1109/TDMR.2025.3636905

Volume

26

Issue

1

First Page

256

Last Page

270