Indoor thermal comfort evaluation of stone houses in Shandong mountainous region of China

Document Type

Article

Publication Date

1-1-2026

Abstract

The varying thermal comfort needs across different building types suggest that current international standards do not fully address all structures, particularly vernacular dwellings. This study examines the winter thermal environment of stone house in Shandong mountainous region, China. A quantitative approach was used, combining subjective questionnaires to capture occupants’ thermal perceptions and field measurements to collect objective data. The results indicate that stone houses maintain lower indoor temperatures (12–17.6°C). To cope with the cold, residents wore thicker clothing (1.32–2.47 clo). A thermal comfort model was established, identifying a neutral temperature of 16.3°C and an acceptable range of 13.8–18.9°C. The thermal expectation value was 16.8°C, slightly higher than the neutral temperature, indicating a preference for warmer conditions. This study offers theoretical guidance for evaluating thermal comfort in Shandong stone houses, with practical implications for their renovation. It also highlights the importance of thermal adaptation in vernacular dwellings globally.

Keywords

field survey, indoor thermal environment, Shandong mountainous region, stone houses, Thermal comfort, vernacular dwellings

Publication Title

Architectural Science Review

ISSN

00038628

DOI

10.1080/00038628.2025.2493813

Volume

69

Issue

2

First Page

199

Last Page

211

Share

COinS