A clinical comparison of conventional, custom tray, extraoral scanning, and photogrammetry facial recording techniques for maxillofacial prosthesis fabrication
Document Type
Article
Publication Date
3-1-2026
Abstract
Statement of problemThe fabrication of facial prostheses is a complex and time-consuming process, requiring the precise recording of facial defects and surrounding tissues. Conventional techniques often face challenges such as soft-tissue compression, involuntary patient movements, and inadequate support for impression materials, leading to inaccuracies. Emerging 3-dimensional (3D) imaging and scanning technologies, such as photogrammetry, offer potential alternatives, yet their clinical accuracy and reliability remain insufficiently validated.PurposeThe purpose of this clinical study was to compare the accuracy, procedural efficiency, and material use of 4 maxillofacial recording techniques: conventional alginate impressions, custom trays with alginate, extraoral scanning (Revopoint MIRACO 3D Scanner), and photogrammetry (Polycam app) in the fabrication of nasal prostheses.Material and methodsA total of 28 maxillofacial recording specimens were obtained from 7 participants (aged 18 to 24 years) using 4 distinct techniques: conventional alginate impressions (Conv), custom trays with alginate (Cust), extraoral scanning using the Revopoint MIRACO 3D Scanner (Ex-S), and photogrammetry using the Polycam app (Ph-S). Digital maxillofacial casts generated with an intraoral scanner (Primescan; Dentsply Sirona) served as the reference standard. The accuracy of the specimens was assessed using 3D deviation measurements in a software program (Geomagic Control X), and procedural time was recorded using a digital stopwatch. Both outcomes were analyzed using a repeated-measures mixed-effects model, followed by Bonferroni-adjusted pairwise comparisons (α=.05). Material waste was recorded and analyzed descriptively.ResultsThe Ex-S group demonstrated the highest accuracy, with a mean deviation of 54 ±18 µm, followed by the Cust group (85 ±32 µm) and the Ph-S group (87 ±13 µm). The Conv group showed the largest deviation (147 ±56 µm). A repeated-measures mixed-effects model revealed a significant main effect of technique (P< .001). Pairwise comparisons showed that Conv had significantly higher deviations than Ex-S (P=.011). No statistically significant differences were found between Conv and Cust (P=.058), Cust and Ex-S (P=.059), Conv and Ph-S (P=.263), Cust and Ph-S (P>.999), or Ex-S and Ph-S (P=.068). Procedural time also varied significantly among groups. The Conv group recorded the longest time (45.0 ±3.0 minutes), followed by Cust (6.0 ±1.0 minutes), Ex-S (3.6 ±0.5 minutes), and Ph-S (3.0 ±0.5 minutes). Pairwise comparisons indicated that Conv was significantly longer than all other groups (P< .001 for all) and that Cust was significantly longer than both Ex-S (P=.001) and Ph-S (P< .001). No significant difference was observed between Ex-S and Ph-S (P=.180). Material waste was highest in the Conv group (230 ±45 g) and reduced in the Cust group (116 ±18 g). The digital groups Ex-S and Ph-S produced no material waste.ConclusionsDigital recording techniques, particularly extraoral scanning and photogrammetry, provide better accuracy, reduce material waste, and enhance procedural efficiency compared with conventional techniques. Custom trays offer a suitable transitional solution for practitioners moving toward fully digital workflows.
Keywords
Adolescent; Alginates; Dental Impression Technique; Female; Humans; Imaging, Three-Dimensional; Male; Maxillofacial Prosthesis; Photogrammetry; Prosthesis Design; Reproducibility of Results; Young Adult, alginic acid
Publication Title
Journal of Prosthetic Dentistry
ISSN
0022-3913
DOI
10.1016/j.prosdent.2025.05.018
Recommended Citation
Buzayan, Muaiyed Mahmoud; Elkezza, Aeman H.; Kadir, Mohammed Rafiq Abdul; Loo, Koay Chee; and Enr, Tsai Jing, "A clinical comparison of conventional, custom tray, extraoral scanning, and photogrammetry facial recording techniques for maxillofacial prosthesis fabrication" (2026). Research Publications (2026 to 2030). 1033.
https://knova.um.edu.my/research_publications_2026_2030/1033
Volume
135
Issue
3
First Page
625
Last Page
631
Publisher
Elsevier Inc.