Assessment of maximum power point trackers performance using direct and indirect control methods

Document Type

Article

Publication Date

10-1-2020

Abstract

The direct and indirect control methods are commonly used for maximum power point tracker (MPPT) of photovoltaic (PV) systems. Due to the absence of the literature that assess their performance in a comprehensive way, this work attempts to analyze the effectiveness of both control methods for the perturb and observe (P&O) MPPT algorithm. The MATLAB/Simulink simulation is verified experimentally using a PV array simulator and the dSPACE DS1104 DSP board driving a buck-boost converter. The results show that the indirect method exhibits lower steady-state oscillation and is less sensitive to rapid irradiance change and load variations. It increases the steady-state efficiency by 1.6%. Furthermore, under irradiance and load step changes, the transient efficiency increases by 29% and 30%, respectively. Based on these findings, it is envisaged that the indirect method is more suitable to be used as the controller in conjunction with the MPPT algorithm.

Keywords

Direct control, Indirect control, Maximum power point tracking, Perturb and observe, Photovoltaic system

Divisions

sch_ecs

Funders

Ministry of International Trade and Industry (MITI), Malaysia,GA016-2019,Ministry of Education, Malaysia,FP019-2018A,Universiti Malaya,IIRG011A-2019

Publication Title

International Transactions on Electrical Energy Systems

Volume

30

Issue

10

Publisher

Wiley-Hindawi

Publisher Location

ADAM HOUSE, 3RD FL, 1 FITZROY SQ, LONDON, WIT 5HE, ENGLAND

This document is currently not available here.

Share

COinS