Abstract
Comparison of UV, H2O2, Fe2+, UV/H2O2, UV/Fe2+, Fe2+/H2O2 and UV/Fe2+/H2O2 processes for the removal of percentage color, COD and electrical energy per order from the effluent distillery industry. The results showed that, UV/Fe2+/H2O2 process yield higher percentage color and COD removal with low electrical energy per order than UV, UV/H2O2, UV/Fe2+ process. To obtain the UV/Fe2+/H2O2 process performance by operating various parameters on the percentage color and COD removal using response surface methodology. A Regression quadratic model describing the percentage color and COD removal efficiency of UV/Fe2+/H2O2 process were developed and validate by analysis of variance. Experimental results showed that, UV/Fe2+/H2O2 process can effectively reduced 96.50% of color and 84.40% of COD removal of the distillery industry wastewater under the optimum conditions such as Fe2+-1.50 mM, H2O2-200 mM, COD-1500 ppm and pH-3.2, respectively. Result concluded that, UV/Fe2+/H2O2 process can be used effectively for the treatment of real industrial effluent.
Keywords
UV/Fe2+/H2O2 process, Distillery, Color and COD removal, Electrical energy per order, RSM
Divisions
fac_eng
Funders
Ministry of Higher Education Malaysia: University of Malaya High Impact Research Grant (HIR-MOHE-D000037-16001)
Publication Title
Water Resources and Industry
Volume
18
Publisher
Elsevier