Determination of percentage depth dose for 6 and 10 MV x-rays using Ge-doped optical fibre and TLD-100
Document Type
Article
Publication Date
1-1-2002
Abstract
Percentage depth doses for 6 and 10 MV x-ray beams from a linear accelerator were measured using ~1 cm long (~0.3 mg) Ge-doped optical fibre as a thermoluminescence dosimeter for two field sizes, 5 × 5 and 10 × 10 cm2. The results indicate that the Ge-doped optical fibre dosimeter is in good agreement with the results from a PTW 30001 cylindrical ionisation chamber and TLD-100. For 6 MV x-ray beams we observe that the depth of maximum dose dmax is 1.5 and 2 cm for field sizes of 5 × 5 and 10 × 10 cm2 respectively. For 10 MV dmax is 2 cm for a field size of 5 × 5 cm2 and 2.5 cm for a 10 × 10 cm2 field.
Keywords
Optics, quantum optics and lasers, Medical physics, Condensed matter: structural, mechanical & thermal
Publication Title
Journal of Radiological Protection
ISSN
0952-4746
Recommended Citation
Abdulla, Y.A.; Amin, Y.M.; and Khoo, H.B., "Determination of percentage depth dose for 6 and 10 MV x-rays using Ge-doped optical fibre and TLD-100" (2002). Research Publications (2000 to 2005). 398.
https://knova.um.edu.my/research_publications_2000_2005/398
Divisions
Science
Volume
22
Issue
4
Publisher
Institute of Physics