Investigation of some commercial TLD chips/discs as UV dosimeters

Document Type

Article

Publication Date

6-1-2001

Abstract

Using a deuterium UV source, we have investigated the response of a number of commercially available thermoluminescence (TL) dosimeters (TLDs) to UV radiation (UVR), including LiF : Mg, Cu, P (TLD-100 H), CaF2 : Dy (TLD-200), CaF2 : Mn (TLD-400), Al2O3 (TLD-500), 7LiF : Mg, Cu, P (TLD-700 H) and CaSO4 : Dy (TLD-900). The intrinsic method was used to detect UVR, while trap depth and frequency factors were estimated using the initial rise method. We have studied TL intensity as a function of exposure time, observing high sensitivity of TLD-500 to UVR. Conversely, TLD-400 displays weak sensitivity to these same radiations. Although TLD-900 and TLD-200 are both less sensitive to UVR than TLD-500, they each provide a linear response to UVR. The possible use of these phosphors as UV dosimeters has been further appraised, examining thermal fading effects and fading due to light exposure.

Keywords

TL material, UV radiation, Trap depth and frequency factor

Divisions

PHYSICS

Publication Title

Radiation Physics and Chemistry

Volume

61

Issue

3-6

Publisher

Elsevier